Home |
Automotive Testing Products |
Conditioned Air Supply Systems |
Drive In Chambers |
HVAC Testing Products |
Environmental Rooms |
Custom Air Handlers |
Careers |
|
|
AUTOMOTIVE A/C SYSTEM
CALORIMETER
Climatic
Testing Systems, Inc.’s A/C System Calorimeters are designed
to provide the customer with extreme accuracy, repeatability
and flexibility in the determination of automotive air
conditioning system thermal capacities.
The CTS System Calorimeter is designed to simulate all of the spaces in and around a vehicle under extreme operating conditions. The system calorimeters utilize up to three (3) Walk-In Chambers for the control of ambient conditions for the condenser and evaporator(s)/heater core(s) and one (1) Reach-In Chamber for the control of ambient conditions around the compressor. These ambient conditions are precisely controlled and recorded. Air Enthalpy Tunnels are used to determine system air-flows and the psychrometric conditions of the air as it exits the test piece. The code testers include AMCA nozzles with a bypass system to allow a wide range of system air-flows without sacrificing system accuracy. The calorimeter offers control over such parameters as ambient temperature and humidity, test piece air flow, compressor speed, discharge pressure, condenser inlet temperature, expansion device inlet temperature, suction temperature, heater core inlet temperature, pressures and flows, etc. The calorimeter is controlled by an automated computer data acquisition and control system and is designed for heat balances of ±2% with a repeatability of ±1%. | |
|
| |||
| Typical Performance Specifications | |||
| Parameter | Range | Stability | |
|
| |||
| Compressor Chamber Temperature | Ambient +5°F to 250°F | ± 0.5°F | |
|
| |||
| Compressor Speed | 400 to 6000 RPM | ± 5 RPM | |
|
| |||
| Discharge Pressure | 150 to 5000 Psig | ± 2.5 Psig | |
|
| |||
| Suction Pressure | 0 to 100 Psig | ± 0.5 Psig | |
|
| |||
| Liquid Temperature | 60 to 210°F | ± 0.2°F | |
|
| |||
| Evaporator Core Air Flow | 50 to 1500 cfm | ± 1% | |
|
|
|||
| Condenser Air Flow | 500 to 5000 cfm | ± 1% | |
|
|
|||
| Condenser Room Temperature | 40 to 140°F | ± 0.2°F | |
|
|
|||
| Evaporator Room Temperature | 15 to 140°F | ± 0.2°F | |
|
|
|||
| Evaporator Room Dew Point | 35 to 135°F | ± 0.2°F | |
|
|
|||
| Glycol Flow | 0 to 12 GPM | ± 0.2 GPM ± 0.75 GPM | |
|
|
|||
| Glycol Temperature | 60 to 230°F | ± 0.2°F | |
|
|
|||
|
| ||
| Capacity Range | ||
| > | Passenger Car & Truck: up to 6 tons | |
| > | Bus and Van: up to 20 tons | |
|
|
||
| Performance Measurement | ||
| > | 2% agreement or better heat balance air-side to refrigerant side | |
| > | 1% repeatability of test results | |
|
|
||
| Software Features | ||
| > | Editing of test program | |
| > | Automatic test sequencing | |
| > | Loop calibration and calibration reports | |
| > | Hardware checkout routine | |
| > | Stability monitoring | |
| > | Real-time tolerance adjustments | |
| > | Real-time history graphing capability | |
| > | Automatic test report generation | |
| > | Data file management | |
|
| ||
| Options | ||
| > | Oil in circulation control | |
| > | Auxiliary evaporator systems | |
| > | D.C. blower controls | |
| The specifications shown above are typical. Contact CTS to discuss your testing needs today! | ||
|
|
|